Explanation on the Debug Panel in MakeIt Software
Control+Shift+P(Command+Shift+P for mac) to bring out the panel.

Ensure the laser is powered on and connected either via USB or WiFi.
Command you might need to use:
Open LOG
Open G-code File
Homing
Rise
Descend
Cooling System On/Off
Exhaust System On/Off
Air Assist On/Off
Upload G-code File
Continue
Pause
Cancel
Detect Rotary Set
Test Rotary Set
OTA File Upload
Open LOG, which can also be found in settings. Open Log

Open G-code File. G-code File
Homing: To let the laser module return to the rear left corner for homing.
Rise: To let the laser rise to the full height
Descend: To lower the laser to idle mode.
- Note: While Vision model is set to rise automatically once powering on, it won’t lower once you power it off.
- You can also go to settings to lower it.
Transportation Mode
Idle Mode
- You can also go to settings to lower it.
Cooling System On/Off: To test if the laser module fan is working on not.
Exhaust System On/Off: To test if the exhaust fan is working or not.
Air Assist On/Off: To test if the air assist set is working or not. Vibrating if on.
Upload G-code File: To test if there is an issue with the laser’s performance.
Continue: To resume the task after pausing midway.
Pause: To mid-stop a task. you may also open the lid or simply click Pause in Processing Window.
Cancel: To cancel a task. You may also long-press the start button on the front or click Cancel in Processing Window.
Detect Rotary Set: To check if the rotary set is installed properly with the motor wire inserted.
Test Rotary Set: To test if the rotary set can rotate or not to engrave tumblers
OTA file Upload: To resolve firmware abnormality issue.